Print Back
These fibers are ideally suited for use with both 650 and 850 nm active devices. For medical applications, they are USP Class VI non toxic, biocompatible and sterilizable. Part of the HCS fiber family, the 200 and 400 µm sized fibers are compatible with crimp and cleave termination.
Unit of Measure

Optical Properties

Type

N/A Multimode Step-Index

Numerical Aperture

N/A 0.37

Attenuation

N/A @ 850 nm, ≤ 8 dB/km

Water Content

N/A Low OH

Dimensions/Geometric Properties

Core Diameter

N/A 400 ± 8 µm

HCS® Cladding Diameter

N/A 430 +5 / -10 µm

ETFE Buffer Diameter

N/A 730 ± 30 µm

Core/Clad Offset

N/A ≤ 8 µm

Crimp & Cleave Compatible

N/A Yes

Coating/Buffer Descriptions

Cladding Material

N/A HCS

Buffer Material

N/A ETFE

Operating Temperature

N/A -65 to +125 ºC

Mechanical and Testing Data

Short-Term Bend Radius

N/A ≥ 29 mm

Long-Term Bend Radius

N/A ≥ 47 mm

Proof Test Level

N/A ≥ 100 kpsi0.689 GPa

How To Order:

Product Description Code

N/A HCP-M0400T

Order From Location

N/A AVON LOCATION
1.888.438.9936 toll-free in the United States and Canada
1.860.678.0371 from outside the U.S.A.
55 Darling Drive
Avon, CT 06001, USA

Order By Item #

N/A CF01493-12

Applications For Any And/Or All Of These Products

N/A Automotive Avionics Communications Electric Power Generation SCADA Systems High-Power Laser Delivery Illumination Industrial Automation / Control Laser Therapy and Surgery LED and Laser Source Coupling Medical lasers Near-IR Spectroscopy Nuclear Plasma Diagnostics Optical Pyrometry Semiconductor Equipment Sensing Short- to medium distance communications

Options

N/A Buffer Color Buffer Diameter Buffer Material Proof Test