Outdoor/Indoor cables combine the design requirements of traditional outdoor cables meeting GR20 specifications while adding flame resistance and safety features of an indoor cable meeting either riser or plenum flame spread. The result is a unique, dual-purpose cable that can save time and money by allowing OSP applications to flow seamlessly indoors, using a single cable to reach inside locations without splicing.

Unit of Measure
Items
AccuRibbon-DC-TL

AccuRibbon® DC TL Cables

OPTION1-DT-Armored-Outdoor-Indoor-Cable-162

OPTION1™ DT Outdoor/Indoor Armored Cables

OPTION1-DT-Outdoor-Indoor-Cable-161

OPTION1™ DT Outdoor/Indoor Cables

Plenum-Xcel-Indoor-Outdoor-Cable-osp-140

PlenumXcel™ Outdoor/Indoor Loose Tube Plenum Cables

AccuTube® + 1728-Fiber Rollable Ribbon (RR) in Loose Tube Cable xSection

AccuTube® Rollable Ribbon (RR) Building Cable
Applications N/A Outdoor/Indoor
Mechanical Rating N/A GR20 N/A GR20 N/A GR20 N/A GR20 N/A
Construction N/A Ribbon N/A Loose Tube N/A Loose Tube N/A Loose Tube N/A Loose Tube
Aerial or Underground N/A Underground N/A Underground (Duct) N/A Underground (Duct) N/A Underground (Duct) N/A Underground (Duct)
Dielectric or Metallic N/A Dielectric N/A Metallic N/A Dielectric N/A Dielectric N/A
Waterblocking Component N/A Gel Free N/A Gel Free N/A Gel Free N/A DryBlock® N/A
Fiber Count N/A N/A N/A N/A N/A 1728
Cable Outer Diameter N/A N/A N/A N/A N/A 1.00 in25.4 mm
Cable Weight N/A N/A N/A N/A N/A 634 kg/km425 lb/kft
Minimum Bend Radius, Storage Coils N/A
Features and Benefits N/A
Cable Type N/A N/A N/A N/A N/A Rollable Ribbon
Indoor or I/O N/A
Flame Spread Rating N/A
Fiber Coating N/A
ComCode N/A
Core Tube N/A N/A N/A N/A N/A 0.28 Inch7.2 mm
CPR Rating N/A N/A N/A N/A N/A B2ca-s1a,d0,a1
DoP Lookup N/A N/A N/A N/A N/A ATIO-1728-A-D
Dynamic Condition/Loaded N/A N/A N/A N/A N/A 40 x OD in
Static Condition/Unloaded N/A N/A N/A N/A N/A 10 x OD in
Storage Coils N/A N/A N/A N/A N/A 40 x OD in
Storage Temperature N/A N/A N/A N/A N/A -40 to 70 ºC-40 to 158 ºF
Performance Standard N/A N/A N/A N/A N/A

The AccuTube RR Indoor/Outdoor Building Cable meets all or portions
of Telcordia GR-20 CORE Issue 4 and ANSI/ICEA S-87-640. Dual-rated
cables are UL listed as compliant with NEC Article 770 as Type OFNR.

Installation Temperature N/A N/A N/A N/A N/A -20 to 60 ºC-4 to 140 ºF
Operation Temperature N/A N/A N/A N/A N/A -40 to 70 ºC-40 to 158 ºF
Maximum Long Term Load N/A N/A N/A N/A N/A 333 lb1412 N
Maximum Tensile Rating N/A N/A N/A N/A N/A 2670 N600 lb
Compressive Strength N/A N/A N/A N/A N/A 220 N/cm max