Designed specifically for indoor use, this design with 2.5 mm outer jacket is constructed with low smoke zero halogen (LSZH) cable materials from GiHCS® optical fibers. They are appropriate for indoor riser installations in enclosed or sealed locations. These cables are crimp and cleave compatible with ST or SC connectors. LSZH materials also offer a wider operating temperature range than comparable HCS cables.
Type |
N/A Multimode Graded-Index |
Attenuation |
N/A @ 1300 nm, ≤ 2 dB/km@ 850 nm, ≤ 4 dB/km |
Fiber Specifications |
N/A
F14404, 62.5 µm GiHCS® Optical Fibers |
Fiber Core Diameter |
N/A 62.5 µm |
Fiber Geometry |
N/A 62.5/200/230 µm |
Construction |
N/A Zipcord |
Specialty Testing [Cyclic flexing] |
N/A > 50,000 cycles |
Sub-Unit Diameter |
N/A 2.5 mm |
Outer Cable Diameter |
N/A 2.5 x 5.2 mm |
Cable Weight |
N/A 11.0 kg/km |
Outer Jacket Color |
N/A Orange |
Outer Jacket Material |
N/A LSZH |
Strength Member |
N/A Aramid Yarn |
Installation Load Maximum |
N/A 165 lb734 N |
Operating Load Maximum |
N/A 85 lb378 N |
Minimum Bend Operating |
N/A 25 mm |
Operating Temperature |
N/A -20 to +80 ºC |
Storage Temperature |
N/A -20 to +80 ºC |
Intended Location |
N/A Indoor |
Minimum Bend Installation |
N/A 25 mm |
Qualified to the following US, Canadian and International Standards |
N/A Qualified to the following US, Canadian and International Standards. OFSNR/FT-4 Riser, US and Canadian UL 1666, Flammability IEC 60332-3 (for zipcord, 2-fiber & 4-fiber cables), smoke density IEC 61034, Halogen Gas Emissions IEC 60745-1, Acid Gas Emissions IEC 60745-2 |
Product Description Code |
N/A HCU-MF062T-A02ZZ |
Order From Location |
N/A
AVON LOCATION 1.888.438.9936 toll-free in the United States and Canada 1.860.678.0371 from outside the U.S.A. 55 Darling Drive Avon, CT 06001, USA |
Order By Item # |
N/A C26643 |
Note |
N/A The operating temperature ranges are general guidelines. Consult with our Technical Sales department to determine the optimal coating and jacketing material for your specific application. 1.860.678.6636. OFS reserves the right to make changes to the prices and product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any OFS warranties or specifications relating to any of its products or services. |
Typical Applications |
N/A
Electrical Substation Automation and Controls Factory Automation Industrial Networks Railway Station Automation and Controls Windpower Automation and Controls |