Outdoor/Indoor cables combine the design requirements of traditional outdoor cables meeting GR20 specifications while adding flame resistance and safety features of an indoor cable meeting either riser or plenum flame spread. The result is a unique, dual-purpose cable that can save time and money by allowing OSP applications to flow seamlessly indoors, using a single cable to reach inside locations without splicing.

1 - 12 of 12 | Results Per Page | View | Unit of Measure
1 

Item #

Applications

Construction

Aerial or Underground

Dielectric or Metallic

Waterblocking Component

Cable Type

Indoor or I/O

Flame Spread Rating

Fiber Coating

Core Tube

CPR Rating

DoP Lookup

Dynamic Condition/Loaded

Static Condition/Unloaded

Storage Coils

Storage Temperature

Performance Standard

Installation Temperature

Operation Temperature

Maximum Long Term Load

Maximum Tensile Rating

Compressive Strength

N/A Indoor/Outdoor N/A Tight Buffer N/A Underground N/A Dielectric N/A Waterblocking aramid N/A BackBone N/A I/O N/A Dual Rated OFNR & Non-Halogen -3C Rated N/A Tight Buffer UV N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Indoor/Outdoor N/A Tight Buffer N/A Underground N/A Dielectric N/A Waterblocking aramid N/A BackBone N/A I/O N/A RISER OFNR (UL1666/UL1685) N/A Tight Buffer LSPVC N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Outdoor/Indoor N/A Ribbon N/A Underground N/A Dielectric N/A Gel Free N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Indoor/Outdoor N/A Ribbon N/A Underground N/A Dielectric N/A Waterblocking Tape N/A BackBone N/A I/O N/A Dual Flame Rated (OFNR and CPR Rated) N/A Ribbon N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Indoor/Outdoor N/A Ribbon N/A Underground N/A Dielectric N/A Waterblocking threads or tape N/A Rollable Ribbon N/A I/O N/A Dual Rated OFNR & CPR N/A Rollable Ribbon N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Indoor/Outdoor N/A Tight Buffer N/A MDU, In-home wiring N/A Dielectric N/A Waterblocking aramid N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Indoor/Outdoor N/A Tight Buffer N/A Underground N/A Metallic N/A Waterblocking aramid N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Outdoor/Indoor N/A Loose Tube N/A Underground (Duct) N/A Metallic N/A Gel Free N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Outdoor/Indoor N/A Loose Tube N/A Underground (Duct) N/A Dielectric N/A Gel Free N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Outdoor/Indoor N/A Loose Tube N/A Underground (Duct) N/A Dielectric N/A DryBlock® N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A Outdoor/Indoor N/A Loose Tube N/A Underground (Duct) N/A N/A N/A Rollable Ribbon N/A N/A N/A N/A 0.28 Inch7.2 mm N/A B2ca-s1a,d0,a1 N/A ATIO-1728-A-D N/A 40 x OD in N/A 10 x OD in N/A 40 x OD in N/A -40 to 70 ºC-40 to 158 ºF N/A

The AccuTube RR Indoor/Outdoor Building Cable meets all or portions
of Telcordia GR-20 CORE Issue 4 and ANSI/ICEA S-87-640. Dual-rated
cables are UL listed as compliant with NEC Article 770 as Type OFNR.

N/A -20 to 60 ºC-4 to 140 ºF N/A -40 to 70 ºC-40 to 158 ºF N/A 333 lb1412 N N/A 2670 N600 lb N/A 220 N/cm max
1 - 12 of 12 | Results Per Page | View | Unit of Measure
1